What came first: the chicken or the egg? In technical files the answer is simple: first comes the product, then the standard. In 1993, when Nichia introduced the blue LED (based on GaN), the issue of photo biological safety was taken into consideration. The International Electrotechnical Commission (IEC) decided to include LEDs in the laser product category and related norms (IEC 60825). This decision was based on the use of infrared LED in the fibre communication system due to its very narrow band.

A few years later — 1996 — IESNA published ANSI/IESNA RP27.1, “Photobiological safety for lamps and lamp systems – general requirements,” providing some norms for sources other than laser.

In 2002, the International Commission on Illumination adopted the main part of ANSI/IESNA RP27.1 as the basis for a new norm S009/E-2002: “Photobiological safety of lamps and lamp systems”; four years later the fast improvement and diffusion of LEDs in other fields led the IEC to draft the 60825, a very severe Norm for “general purpose” LED. From now on, LEDs are no longer considered as a LASER equivalent source.

Around 2006 IEC adopted the guidelines specified in S009/E-2002 jointly with IEC 62471:2006 “Photobiological safety of lamps and lamp systems;” two years later the European edition of EN 62471 was published. It provides guidance for evaluating the photobiological safety of lamps and lamp systems, including luminaires. It specifies the exposure limits, reference measurement technique and classification scheme for evaluating and controlling photobiological hazards from all electrically powered incoherent broadband sources of optical radiation, including LEDs but excluding lasers, in the wavelength range from 200 nm through 3000 nm. In particular, some limit values are specified based on six risk categories for human skin and eyes up to 8 hours of exposition, considered as a standard working time.

Photobiological safety of lamps: EN 62471

Light radiation can damage the skin and eyes. Any light source can cause damage, not just LEDs. European legislation obliges manufacturers to perform laboratory tests and writing on the lamp the risk category (if present). More, the emission limits shall not be exceeded. Test to run, risk classes and emission limits are defined in EN 62471. The tests and emission limits are not easy to understand because they require specific technical knowledge and only experts and equipped laboratories can assess the lamp hazards. What we can do is to understand the hazard of the various classes and if there are “risk free” lamps.

The potential damage from the light varies with the radiation wavelength and the quantity received. The quantity is given by the power for the exposure time. Intense radiation requires less time to cause damage at a lesser intensity.

Here’s an example to clarify the context: you can get sunburned if exposed for one hour on July 21 at noon, whereas you would require eight hours of exposure in March.

 

The radiance and irradiance measurements are carried out at the distance at which it produces an illuminance of 500 lux and to not less than 200 mm in the case of general lighting devices and 200 mm for all others.

EN 62471 defines the following the exposure limits for the different groups…

Lamps belonging to Group 3 cannot be used for general lighting.

According to the typical spectral emission, just a few lamps may be dangerous:

In these cases, the lamps must bear on the packaging the risk group.

With regard to blue light, whereas the values stated above it is possible to define a value of the illumination (at the level of the eyes) as a function of the colour temperature (CCT) of the lamp, under which the exposure is equal to or less than the group 1:

In the chart above, a higher colour temperature (CCT) is related to a higher power in the blue wavelength. In other words, the risk can be simply checked by a measurement of illuminance with a cheap and easy to use instrument: a lux meter.

Fausto Martin is an electrical engineer in Italy and a visiting professor at Madrid University (Spain).

Related Articles


Changing Scene


Design

  • Axis Lighting: Hagersville Library, ON – Lighting Project Highlight

    Axis Lighting: Hagersville Library, ON – Lighting Project Highlight

    The newly opened Hagersville Library + Active Living Centre brings together community, learning, and wellness within a flexible, multi-use environment. The facility includes a 3,900-sf library, 2,000 sf atrium, 840 sf program room, and a 4,855 sf multi-functional rental space designed to support a wide range of activities. Axis Lighting’s Zen series was selected to… Read More…

  • Artika: What Are Lumens in Lighting? How to Read Brightness Specs Like a Pro

    Artika: What Are Lumens in Lighting? How to Read Brightness Specs Like a Pro

    Lumens measure the total amount of visible light a bulb or fixture produces, so more lumens means a brighter light. Shopping for lighting used to be simple. You grabbed a 60-watt bulb for the bedroom, a 100-watt bulb for the kitchen, and called it a day. Today, with energy-efficient LEDs, watts no longer tell you… Read More…


New Products

  • JDRF Electromag: The Autonomy Touch Screen – Lighting Control Solution

    JDRF Electromag: The Autonomy Touch Screen – Lighting Control Solution

    The Autonomy Touch Screen automatically pairs with co-located sensors and updates the GUI based on the lighting arrangement grouping configuration. Users can pair their smartphone to the Touch Screen through NFC with a simple tap to gain access to the lighting system from the mobile application. The Touch Screen provides a visual interface to control… Read More…

  • Eralux: ALPS E3 HYDRO – Backlit Flat Panel

    Eralux: ALPS E3 HYDRO – Backlit Flat Panel

    The ALPS E3 series is a backlit flat panel designed with optimal LED placement to ensure a uniformly lit space. It features a switchable CCT and power driver that allows endless flexibility at the install site, as well as a 125 LPW performance. The additional Level 2 NSF rating of the ALPS E3 HYDRO makes… Read More…