Light Replaces the Needle

Lighting Tech

 

Empa and the University Hospital Zurich have joined forces to develop a sensor that gauges blood sugar through skin contact. And best of all: No blood samples are necessary, not even to calibrate the sensor. “Glucolight” is initially to be used in premature babies to avoid hypoglycemia and subsequent brain damage.

One in 12 children are born prematurely in Switzerland. If hypoglycemia develops in these premature babies and persists for over an hour, it can affect brain development. In order to prevent this, the babies’ blood sugar levels need to be measured at regular intervals, which until now inevitably meant taking blood samples. Drawing blood regularly from the sensitive little ones for hours on end, however, is impossible as the blood loss and stress would be too great. In a project funded by the Swiss National Science Foundation (SNSF), Empa and the University Hospital Zurich thus teamed up to develop the sensor “Glucolight,” which gauges the blood sugar level through the skin without taking any blood. Although skin sensors already exist, they have to be calibrated before use, which means that the skin’s permeability value needs to be known. In order to establish this, the blood sugar value has to be determined via a blood sample and the glucose concentration on the skin measured. Based on these readings, the permeability can then be calculated and the sensor calibrated.  

Photo:  Credit: Empa 

A different method to previous sensors

Glucolight spares the premature babies blood samples and enables the blood sugar level to be monitored permanently thanks to the sensor’s novel measuring technology, which comprises several parts: 

• amicrodialysis measuring head, which was developed at the University Hospital Zurich, with a “smart” membrane developed at Empa

• light sources

• a pump

• a microfluidics chip with a fluorometer, also developed at the University Hospital Zurich

The smart Empa membrane contains special dye molecules, known as spiropyrans. If UV light is beamed onto these spiropyran molecules, they alter their chemical structure and become charged (polar). When irradiated with visible light, they revert to their original, neutral structure. As a result, the membrane “opens” if irradiated with UV light and glucose molecules diffuse relatively easily through the membrane from the skin. If irradiated with visible light, considerably fewer glucose molecules pass through the membrane.  

The measurement involves sticking the measuring head, which is around three centimeters in size, to the baby’s skin and irradiating it with visible light; some glucose molecules diffuse through the membrane from the skin. On the other side of the membrane, the glucose is mixed with a fluid and pumped through the microfluidics chip, while enzymes are added to trigger a reaction. During the reaction, a fluorescence appears, which the fluorometer measures, and the computer uses the reading to calculate the glucose concentration. The process is then repeated with UV light. The computer then uses these two different readings to calculate the premature baby’s blood sugar level.  

Research with and on Glucolight continues

The researchers filed a patent application for Glucolight in mid-2014 and the first clinical studies are scheduled at the University Hospital Zurich for 2015. However, it could be years before the use of Glucolight becomes standard. Empa and the University Hospital Zurich are currently in negotiations with partners for the industrial production of the sensor. For the future, the researchers also envisage the use of Glucolight in other fields, such as diabetes. 

 

Related Articles


Changing Scene

  • Aug 6, 2025 - Hèmèra Announces Acquistion by Industry Professionals Francois Renaud, Matthew Curatolo & Nicholas Cohen

    Hèmèra Announces a New Era of Innovation & Leadership

    Hèmèra has announced that it has been acquired by industry professionals François Renaud, Matthew Curatolo, and Nicolas Cohen. This acquisition marks the beginning of an exciting new era for Hèmèra, as the new leadership team is poised to build on the company’s legacy of delivering innovative, high-performance lighting solutions to discerning customers. The new leadership… Read More…

  • July 28, 2025 - Eureka Wins Multiple SIT Furniture Design Awards

    Eureka Wins Multiple SIT Furniture Design Awards

    Eureka is pleased to announce that it has received 2025 SIT Furniture Design Awards for its Junction, Lattice, and Velia luminaires. SIT Furniture Design Award was created to celebrate and share the remarkable work of furniture designers and those who use furniture in their projects. The creativity, innovative vision, and accessibility of the furniture design… Read More…


Design


New Products

  • Cristal: CCLPD-DMX – 0-10V DMX Relay Panels

    Cristal: CCLPD-DMX – 0-10V DMX Relay Panels

    The CCLPD-DMX panels of Cristal Contrôle have been designed respecting the same standards as the distribution panels of electrical rooms in modern buildings. Thanks to this standardization, the installation of relay panels with dimming is quick and easy. The series of CCLPD-DMX relay panels is equipped with the DMX communication protocol and is designed to host HID relay… Read More…

  • ABB Emergi-Lite: JMC Series – Steel, Compact, 6V & 12V

    ABB Emergi-Lite: JMC Series – Steel, Compact, 6V & 12V

    ABB Emergi-Lite’s JMC Series battery unit’s emergency lighting system shall consist of fully automatic equipment with two emergency lighting heads. The unit shall be rated V with a capacity of W for 30 minutes of emergency operation. The charger shall be factory set with a charging voltage tolerance of ± 1% to enable a longer… Read More…