The Lumen Maintenance Gap

October 16, 2018

This article is an excerpt from a technical brief, “Understanding LM-80, Lumen Maintenance, and LED Fixture Lifetime,” by Philips Color Kinetics.This article is an excerpt from a technical brief, “Understanding LM-80, Lumen Maintenance, and LED Fixture Lifetime,” by Philips Color Kinetics.

Test results of lumen maintenance in conventional and LED light sources differ considerably. This is known as the lumen maintenance gap. These tests are performed to determine the useful life of a light source. But how do we compare lighting technologies satisfactorily if test results of a same designation do not mean the same thing? These lumen maintenance measurement distinctions are those we will examine in this article, as a clear understanding of this gap will have a significant impact on the installation, maintenance and replacement cost calculations of lighting products. 

As an example of the benefits offered by lumen maintenance, the World Market Center in Las Vegas, Nevada (shown in photo), uses over 8,000 ft (2,438.4 m) of eW Cove Powercore linear LED lighting fixtures from Philips Color Kinetics to illuminate the complex geometries of the atrium in one of its buildings. LED cove lighting offers advantages over conventional cove lights in high-end installations such as this one. With useful life of up to 70,000 hours, and a very low failure rate, LED cove lights virtually guarantee reliable illumination around the clock for many years, without dark spots from lamp outages that can mar the elegant and uniform presentation of a premier space.

Lumen maintenance of LED and traditional light sources

When controlled, LED light sources can have a useful life that lasts considerably longer than the rated life of a conventional lighting source. Here’s an example: the World Market Center in Las Vegas, Nevada (shown in photo) uses over 8,000 ft (2,438.4 m) of eW Cove Powercore linear LED lighting fixtures from Philips Color Kinetics to illuminate the complex geometries of the atrium in one of its buildings. LED cove lighting offers advantages over conventional cove lights in high-end installations such as this one. With useful life of up to 70,000 hours, and a very low failure rate, LED cove lights virtually guarantee reliable illumination around the clock for many years, without dark spots from lamp outages that can mar the elegant and uniform presentation of a premier space.

The following table presents comparative data for the typical useful life range of various light sources.

Testing conventional light sources 

LM-65-14 is a document that defines life testing procedures for compact fluorescent lamps (CFLs), while LM-49-12 defines life testing procedures for incandescent filament lamps. Both publications establish testing conditions, testing sample sizes, and valuation methods used for generalizing test data. 

For CFLs, LM-65 specifies that a statistically valid sample be tested at an ambient temperature varying between 15⁰C and 40⁰C, in a cycle of three hours on and 20 minutes off (CFL life is appreciably shortened by the frequency with which the lamp is turned on and off). The point at which half the lamps fail is the rated average life for that lamp.

For incandescent filament lamps, LM-49 stipulates that a statistically valid sample be tested within the manufacturer’s stated operating temperature range and voltage. Lamps are turned off and allowed to cool to ambient temperature once a day (usually for 15 to 30 minutes). As with CFLs, rated life for incandescent filament lamps is the total operating time at which half the lamps cease to operate. 

Testing conventional LED sources

As of 2014, the technical publication entitled LM-84-14 was introduced as a means to fill a gap created by the lack of standardized LED fixtures and lamps testing methods. Even today, the rated life is calculated according to tests performed on lighting system diodes and not on the overall lamp or fixture system. Unfortunately, at this point, the LM-84 publication has disclosed only light system test parameters and is unable to provide other calculation methodology to issue results that might establish a specific rated life.

Many fixture manufacturers develop their individual interpretation of the life test results and establish in their own way the useful life of light sources. Often, they do not share the extrapolation or evaluation methods, so any comparison between the products of various manufacturers becomes both difficult and imprecise.
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Useful life is not fixture lifetime 

It’s important to keep in mind that useful life and fixture lifetime are two very different things. The useful life of a fixture refers to the lumen maintenance projections of the LED sources integrated into that fixture — in plain English, the number of hours an LED lighting fixture will deliver a sufficient amount of light in a given application. 

Fixture lifetime, on the other hand, has to do with the reliability of the components of an LED lighting fixture as a system, including the electronics, materials, housing, wiring, connectors, seals, and so on. The entire system lasts only as long as the critical component with the shortest life, whether that critical component is a weather seal, an optical element, an LED, or something else. From this point of view, LED light sources are simply one critical component among many, although they are often the most reliable component of the whole lighting system. 

Read the full document here: www.colorkinetics.com/Learn/docs/LEDLifetime.pdf

Related Articles


Changing Scene

  • March 3, 2026 - Leviton - Certolux Visioneering (Viscor) Announces Walter Lai as New Purchasing Manager

    Leviton – Certolux Visioneering (Viscor) Announces Walter Lai as New Purchasing Manager

    Leviton – Certolux Visioneering (Viscor) is excited to welcome Walter Lai CSCMP to the team as Purchasing Manager! Walter brings over 20 years of expertise in purchasing, inventory management, and supply chain operations. His strong background in supplier management, cost optimization, and leading cross-functional teams will be a tremendous asset as they continue to strengthen… Read More…

  • Feb 27, 2026 - Lumorphéa A Designer Lighting Exhibition by Mac’s II Agencies - March 5-15, 2026

    Lumorphéa: A Designer Lighting Exhibition by Mac’s II Agencies – March 5-15, 2026

    Lumorphéa has arrived. Rooted in metamorphosis, Lumorphéa explores the transformative power of light — how it reshapes perception, emotion, and space. Not simply display, but experience. From March 5–15, The Gallery George becomes a living, tactile lighting gallery where product, art, and application collide. Curated installations, project imagery, and sculptural lighting moments invite you to… Read More…


Design

  • RENO Lighting Highlights Rittal Canada Lighting Project

    RENO Lighting Highlights Rittal Canada Lighting Project

    It’s great to see projects grow from one phase to the next! RENO Lighting has partnered with Rittal Canada to supply lighting for their new office and warehouse. As the renovation continues, they are proud to showcase the next step in their transformation. From industrial environments to modern workplaces, each phase requires thoughtful lighting design… Read More…

  • Intertek: DLC Solid State Lighting V6.0 & LUNA V2.0 Fact Sheet – The Next Generation of Lighting Requirements

    Intertek: DLC Solid State Lighting V6.0 & LUNA V2.0 Fact Sheet – The Next Generation of Lighting Requirements

    Stay ahead of evolving rebate requirements with Intertek’s DLC SSL V6.0 & LUNA V2.0 technical guide. This fact sheet breaks down new efficacy thresholds, controls and field-adjustable reporting updates, expanded eligibility, and critical 2026 deadlines that could impact your product listings. Learn how to reduce delisting risk, streamline recertification, and align your testing strategy to… Read More…


New Products

  • Dals: Boulevard Architectural Linear Collection

    Dals: Boulevard Architectural Linear Collection

    Dals Boulevard is more than a fixture, it’s a complete architectural system. A single, disciplined line of light moves effortlessly from ceiling to wall, from interior to exterior, creating continuity across every space it touches. One system, expressed four ways, unified by proportion, performance, and purpose. Available in standard 120V or multi-voltage configurations (120, 277,… Read More…

  • Eralux: OSIRIS – Track Fixture

    Eralux: OSIRIS – Track Fixture

    Eralux’s OSIRIS features a distinctive design with a smooth heatsink and a vertical driver enclosure. It is available in three different sizes and offers power options of 20W, 27W, and 51W, delivering 74-92 lumens per watt. Users can choose from three beam distributions: narrow flood, flood, and wide flood. Made from durable aluminum die-cast material,… Read More…