This is the second of a 2-part introductory series on passive infrared (PIR) sensors. Part 1 highlighted how PIR sensors detect motion, discussed the importance of the sensor lens, and the different types of motion that can be detected. Here in Part 2: proper sensor placement and setting accurate sensitivity levels, as well as how to reduce false triggers and sensor time-outs.

Proper placement

It is essential to take care when placing a PIR sensor. With proper placement, the sensor activates correctly, and the probability of false triggers is reduced. When considering placement, it is helpful to visualize the sensing detection pattern and think about discrete slivers of coverage keeping in mind that there are gaps in coverage. It is also beneficial to consider the range of coverage, the direction in which the occupant would typically travel in an area, and the destination of that travel; for instance, an office worker walking to their desk. The best outcome when using a PIR sensor is to place it so that a person intersects several of the coverage slivers rather than walking straight to the sensor.

There are a few best practices to follow that will help ensure a PIR sensor’s maximum effectiveness and negligible false triggers. When deciding on sensor location, keep in mind that the PIR sensor is activated by a change in temperature. 

Here are a few basic tips:

  • Instead of placing the sensor precisely perpendicular to the door of a room, place it on the side of the room that is diagonal to the door. In that way, when someone walks into the room, the person will break more than one beam of coverage and trigger the sensor.
  • Do not place sensors too close to a room’s door, so that the sensor coverage will not extend to the hallway and be triggered by people walking in a corridor.
  • Place a sensor right above the occupant’s desk to detect micro movements such as flipping a page in a book, moving a mouse, or typing on a keyboard. A common mistake is to place the sensor on the ceiling behind the monitor on an occupant’s desk. In this situation, the monitor shields the occupant’s motion and the sensor will not detect it.
  • Do not place sensors over HVAC ducts as the resulting change in heat temperature may trigger the sensor.
  • Do not place sensors where air blowing from an open window or door would move objects such as curtains, blinds, balloons, hanging plants, or signs in the coverage area.
  • Ensure that the sensor is secured on a solid surface that doesn’t vibrate. Even small vibrations, such as those caused by the air flow from ducts, can cause the sensor to see a change in energy and elicit a false trigger.

Timeouts

Sensors have timeouts to avoid continuous alerts. Timeouts refer to how long the light is lit after it detects movement. For instance, a person walking into a room that has been unoccupied for a long time with the lights off will trigger the sensor and the lights will turn on. The sensor has a single timeout configured to determine when to indicate to the system that the room is no longer occupied. Every time a person moves in the room, the sensor resets the timeout, thereby extending the time the lights remain on. As soon as the person stops moving or leaves the room, the occupancy timer starts running until it reaches the value specified as “occupancy timeout” and then it sends the event to the system that the room is unoccupied and the lights will turn off. 

The actual length of the timeout is determined by how the space is used. For example, in a restroom a longer timeout might be used so that lights do not turn off when someone is in the stall. Longer timeouts may also be used in office spaces or hallways to avoid lights continually turning on/off, which can be distracting to people in the rooms lining the hallway. The length of the timeout can be adjusted on the sensor. 

Adjusting sensitivity levels

Often sensors must be tweaked to accommodate sensitivity issues. For example, vibrations in factories with large machines that generate heat may require decreasing the sensor’s sensitivity.

Less sensitivity will cover a smaller area and often result in fewer false triggers but more sensor timeouts, such as the lights turning off when you are still in a room. More sensitivity will cover a larger area and result in fewer sensor timeouts but you may have more false triggers. 

Traditionally, adjustments for sensitivity have been a manual process. An electrician would need to climb up on a ladder to access the sensor, remove a panel , and then turn a screw on it to increase or decrease sensitivity. Although a simple process, it can be cumbersome to scale when deploying hundreds of sensors in a building and can require a bit of trial and error before achieving the optimal sensitivity level. 

Today’s lighting control systems are moving away from traditional sensitivity adjustment methods. Leading vendors are programming sensitivity mechanisms into their software, which enable easy maintenance and more precise sensitivity modifications. 

Read Part 1 here: https://www.lightingdesignandspecification.ca/best-practices/2284-what-are-pir-sensors-and-why-do-i-need-them.

This article was first published by Osram as an online blog: http://info.osram.us/blog/pir-sensors-why-do-i-need-them

Related Articles


Changing Scene

  • May 29, 2025 - Eureka Wins Three 2025 Red Dot Awards for Product Design

    Eureka Wins Three 2025 Red Dot Awards for Product Design

    Eureka is pleased to announce that its Velia, Cirra, and Junction luminaires have each received a 2025 Red Dot Design Award for Product Design. It is the 11th consecutive year that Eureka products have been honored with this prestigious award, which is a testament to the company’s consistency and relentless drive to design exceptional luminaires.… Read More…

  • Cyclone Lighting Wins 2025 Red Dot Award for Valenza

    Cyclone Lighting Wins 2025 Red Dot Award for Valenza

    Cyclone Lighting is pleased to announce its Valenza luminaire has received a 2025 Red Dot Design Award for Product Design. Valenza’s straight geometric lines are offset and softened by organically inspired rounded edges. Seen from the side, its slender, subtle silhouette virtually disappears, belying the quality and strength of its illumination. Viewed head-on, the assertive… Read More…


Design

  • Graphic Office Interiors Enhance Their Office Space, Incorporating State-Of-The-Art Lighting Solutions

    Graphic Office Interiors Enhance Their Office Space, Incorporating State-Of-The-Art Lighting Solutions

    Graphic Office Interiors, a renowned office design and furnishings company serving Vancouver Island since 1966, embarked on a unique lighting project for their personal office in Saanichton, BC. This project marked the first collaboration between Kelly Inglis of Mac’s II Agencies and Graphic Office Interiors’ in-house registered interior designer, Laura Harlos. Known for their exclusive Steelcase furniture line, modular moveable… Read More…

  • Illuminate Your Project with Modern LED Panels

    Illuminate Your Project with Modern LED Panels

    Lighting plays a crucial role is shaping the ambiance and functionality of any space. At Zaneen, their modern LED Panel collection delivers high-quality lighting solutions with sleek designs, energy efficiency, and customizable options to meet diverse project needs. From trim designs like Harmony Elipse and Harmony Square to frameless panes like Infinite Honeycomb and Infinite Ring, to modular marvels like Infinite Canvas and… Read More…


New Products

  • Legrand Unveils Wattstopper i3:  Next-Generation Lighting & Building Intelligence Solution Powered by KODE Labs

    Legrand Unveils Wattstopper i3:  Next-Generation Lighting & Building Intelligence Solution Powered by KODE Labs

    Legrand has announced the launch of the Wattstopper i3 Platform, a next-generation lighting and building intelligence solution powered by KODE Labs, a recognized name in advanced smart building technology. Wattstopper i3 unites Legrand’s established Wattstopper DLM and Wattstopper PLUS systems under a cohesive interface. With KODE’s award-winning OS at its core, the platform consolidates data… Read More…

  • Acuity: New C1D2 Emergency Exit Combo – HLEMC

    Acuity: New C1D2 Emergency Exit Combo – HLEMC

    The HLEMC from Holophane is a high-performing, IP66 rated emergency exit combo that is designed for use in Class 1, Div 2, groups A, B, C, & D hazardous environments, meeting up to a T3C temperature rating. The HLEMC is designed with a one-piece corrosion-resistant enclosure that is high-impact resistant to protect fixture against elements,… Read More…