Using Encircled Flux Compliant Light Sources For Testing Fibre Optic

October 12, 2016

International standards development organizations including ISO/IEC and ANSI/TIA are updating several key standards documents that affect field-testing of fibre optic cabling. In particular the
standards now describe the use of encircled flux compliant light sources.

Encircled flux refers to the distribution of light exiting the launch fibre of a light source used for testing. An ideal launch condition is one where light intensity is an even radial pattern across the face of the launch fibre. The purpose of the standards is to ensure that different test systems from any manufacturer report the same loss for a given cable under test.

Variation in LED and VCSEL launch patterns means that the optical power injected into the cable under test can result in variances in measured power loss values depending on connector alignment or the rotation of the launch cable. This is especially critical in multimode systems where the large fibre core will accept the uneven distribution from the light source and couple it into the cabling under test.

 

Figure 1 depicts the output from an LED into the launch fibre. While the light is distributed axially through the fibre, the intensity is much higher at the edge of the core (represented by a darker red colour) and a noticeable amount of power is present in the cladding (outer ring), creating an overfilled launch condition.

The results are artificially high loss readings when mandrels are not used on the launch cable or when there is mild misalignment between two connectors.

The reasons are that light in the cladding attenuates very quickly, and if this jumper were connected to the power meter during calibration, the light in the cladding will be detected, though it will dissipate in the cable under test and result in a high insertion loss measurement.

Additionally, when the core is overfilled, small misalignments between two connectors can result in abnormally high loss. Especially if the power distribution is weighted to the outside of the core as depicted in Figure 1.

 

 

Figure 2 depicts the output from a VCSEL, which is a low cost laser used in multimode systems to provide higher bandwidth at longer distances. A VCSEL typically has an elongated output that creates a “blade” of light in the fibre core that maintains its shape as it propagates down the cable.

VCSELs also produce spots of high intensity light that further reduce the even distribution of power. In this diagram the spots appear to be dirt, but are actually intense modes (beams) of light.

Rather than try and control the output pattern of LEDs and VSCELs, the solution to the problem is to use specialized launch cables (in the past called mode conditioning cables) that accept an uneven light pattern, scramble it and emit an even light pattern.

These cables can be used with virtually any LED light source and make it encircled flux compliant. While these specialty cables are expensive, they have the benefit of allowing installers to keep their existing multimode light sources and make them encircled flux compliant by simply replacing the launch cable.

 

Figure 3 depicts an encircled flux launch cord connected to a light source. This cord replaces the standard launch cord when testing the installed cabling. The output from the EF launch cord into the fibre under test has an even distribution pattern that does not extend into the cladding of the fibre. Because the distribution pattern depends on whether the fibre core is 50 or 62.5 micron, the EF cord used for testing must match the core size of the fibre under test.

 

 

 

Multimode fibre optic systems do have limitations when compared to single-mode, but their key advantage is the lower cost of the active equipment in the system. And as multimode systems support data rates of 100Gb/s and more, the loss budgets become increasingly stringent.

Therefore, installers need to utilize every tool and technology available to ensure they obtain accurate test data and give themselves the best probability of a problem-free testing experience.

While the encircled flux testing requirements will slowly make its way into contracts and testing requirements, installers should not delay in ensuring the test cords that accompany their power meters and light sources are made with reference grade connectors.

One last note; even the best connectors, launch cables and testers are useless if the end faces are not kept perfectly clean. It’s critical that technicians apply best practices and clean the ports of the test equipment and test cords every time they are used.

When combined, reference-grade connectors/cords, encircled flux compliant launches and clean connectors will provide the best possible testing experience resulting in fewer failed tests and less time spent troubleshooting.

This article was first published online by Ideal Networks: www.idealnetworks.net/US/EN/News/Using-Encircled-Flux-Compliant-Light-Sources-for-Testing-Fiber-Optic.aspx.

 

 

Related Articles


Changing Scene

  • Jan 14, 2026 - GVA Lighting Promotes Gareth Bruce to Vice President – Sales & Marketing

    GVA Lighting Promotes Gareth Bruce to Vice President – Sales & Marketing

    GVA Lighting is pleased to announce the promotion of Gareth Bruce to Vice President of Sales and Marketing, effective December 5th, 2025. Gareth joined GVA in May 2024 as Regional Sales Manager – Southeast, bringing more than two decades of lighting industry experience from Philips / Signify. He was promoted to Director of North American Sales in September 2024 and has since… Read More…

  • Jan 14, 2026 - Intralec Electrical Products Proudly Representing SATCO NUVO Lighting Solutions

    Intralec Electrical Products Announces SATCO NUVO Representation

    Intralec is proud to represent SATCO | NUVO lighting solutions for commercial, residential, and industrial applications. SATCO | NUVO is a major supplier of lighting products, with solutions for nearly every lighting market across the commercial, residential, and industrial landscape. With over 1.5 million square feet of inventory throughout North America and thousands of products… Read More…


Design

  • EB Horsman: Can LED Roadway Lighting Enhance Road Safety & Efficiency?

    EB Horsman: Can LED Roadway Lighting Enhance Road Safety & Efficiency?

    At EB Horsman, they recognize that effective roadway lighting is a crucial component of public safety. With Lumec’s LED roadway lighting solutions, communities can ensure reliable, high-quality illumination that supports safer travel for everyone, day or night, while also improving energy efficiency and long-term operational performance. High-quality roadway lighting is a critical component of public… Read More…

  • Prolux Lighting & Controls: Project Spotlight – Residential House in the Kootenays

    Prolux Lighting & Controls: Project Spotlight – Residential House in the Kootenays

    Have a look at this custom residential home in the Kootenays, where Prolux utilized the HALO RL6 Slope Ceiling Direct Mount fixtures by Cooper Lighting Solutions designed specifically for sloped ceilings. These luminaires provided consistent, high-quality illumination while maintaining a clean, low-profile ceiling aesthetic. Their direct-mount design allowed for seamless integration throughout the home, supporting… Read More…


New Products

  • Philips Hue Transforms Lighting Design with the Hue SpatialAware Feature That Understands Your Space

    Philips Hue Transforms Lighting Design with the Hue SpatialAware Feature That Understands Your Space

    Signify is introducing Hue SpatialAware, which will transform how Philips Hue users experience light scenes. This feature analyzes the layout of your room and the placement of your Philips Hue lights to create the optimal lighting experience tailored to your unique environment. It’s like having a lighting designer in your pocket, allowing you to experience… Read More…

  • Liteline: New LUNA Fire Driver for 3.5″ Fixture

    Liteline: New LUNA Fire Driver for 3.5″ Fixture

    Introducing a new lower-cost driver option for LUNA Fire! This 12W, 120V driver with TRIAC/ELV dimming is designed to significantly reduce cost while maintaining performance, giving you more flexibility.  The LUNA Fire meets UL 1598 / 2108/ 263, CSA C22.2 #250.0 / 250.2, and ULC-S101 safety and building construction requirements granting inherent 2-hour fire-rated protection. It… Read More…