Money Matters — Retrofit or Relight

Retrofit or Relight

Chris Bailey

The retrofit and relight business is in full swing today. A variety of new LED replacement luminaires, retrofit/conversion kits and lamps are available from a variety of manufacturers, and whether we are talking about a T12 to T8 fluorescent conversion or fluorescent to LED, the economic value proposition and project mechanics are well understood.

The most straightforward applications for retrofit kits typically involve replacing antiquated technology with a more efficient lighting solution which reduces the operational costs (energy & maintenance), maintains or improves visual performance and where the initial cost can be justified through a reasonable payback time period. However, in recent years the high-impact financial nature of some lighting retrofits has necessitated a greater level of front-end coordination with customer operations and accounting personnel. This is especially true when it comes to understanding the dynamics involving repurposing, replacing or modifying fixed assets such as lighting equipment, which for many facilities has been amortized over several decades. As a result, outright replacing luminaires early into predetermined useful life may leave a large balance to be written off as a loss.

Commercial buildings are typically depreciated over 39 years. As a result, fixed lighting systems are frequently depreciated along with the building. Leasehold improvements on the other hand are handled a bit differently and are commonly depreciated over the life of the lease or over the useful life of the asset, whichever is less (e.g., 15 years instead of 39 years). This is because you typically only have to undo and redo leasehold improvements every time a tenant moves out.

Depreciation can optionally be accelerated through segregation. This allows you to divide the building into all of its constituent systems, some of which have a life that is much shorter than 39 years. For instance, if your building has a lighting system with a design-life of 15 years, you could write it off over a 15-year period. While this moves a lot of your depreciation forward and saves you money in the beginning, you have less depreciation to claim in the future.

When it comes time to write off an existing lighting system, this process involves removing all traces of the fixed asset from the balance sheet, so that the related fixed asset account and accumulated depreciation account are reduced.

There are two scenarios under which you may write off an existing lighting system (fixed asset). The first situation, which we will cover here, arises when you are eliminating/removing a fixed asset without receiving any payment in return (e.g., accepting resale or recycling value). This is a common situation where existing lighting systems are being scrapped when they are obsolete or no longer in use and there is no resale market for them. In this case, the owner must reverse any accumulated depreciation and the original asset cost. If the asset is fully depreciated, this is the extent of the process. The second situation, which will not be covered here, arises when the customer sells an asset that is or has been depreciated.

Using the above example, the Best Customer Corporation (BCC) purchases and installs a $150,000 lighting system and recognizes $10,000 of depreciation per year over the following 15 years. At that time, the lighting system is not only fully depreciated, but also ready for the scrap heap. BCC disposes of the lighting system, and records the following entry.

Retrofit Chart 1

A variation on this first situation is to write off a lighting system (fixed asset) that has not yet been completely depreciated. In this situation, write off the remaining undepreciated amount of the asset to a loss account. To use the same example, BCC disposes of the system after 10 years, when it has not yet depreciated $50,000 of the asset’s original $150,000 cost. In this case, BCC records the following entry.

Chart 2

Based on the dynamics at play for the customer, it may be more financially reasonable to upgrade a lighting system and avoid the write-off. This may be especially true in situations where the lighting system is being depreciated along with the building life and a decision to upgrade the lighting occurs early into this timeframe. The generally accepted accounting principles (GAAP) indicate that if a portion of the original asset is being replaced (e.g., lamps, ballast, sockets, reflector, etc.), then theoretically the carrying value of these components should be removed from the accounting records and recorded as a loss in the period of the replacement. This accounting is seldom used in practice because, in general, accounting records for fixed assets are not maintained in the painstaking detail necessary to determine the carrying value of the individual components that comprise each asset. Instead, most companies will capitalize the replacement components (e.g., lighting retrofit kit) under the rationale that the portion of the asset besting replace would have been depreciated sufficiently based on the useful life of the “host asset” so that at the time of replacement, little or no carrying value would remain to be removed.

In summary, lighting professionals and customers must carefully consider the financial variables involved in lighting retrofit and relight projects. These must, at a minimum, be evaluated on a customer-by-customer, and in many cases, building-by-building basis. Where a write-off is not ideal, a strong case can be made for retrofitting versus replacing lighting systems. It is also important to note that there may be other reasons to retrofit versus replace luminaires. These reasons may include, but are certainly not limited to, the impact to productivity through disruption, air quality (from disturbing insulation materials or dust) and of course the initial system cost. Some examples of ideal retrofit product candidates where any or all of the concerns mentioned above are involved would include Kim Lighting’s HID to LED upgrade kits, Beacon Products’ LRK series, Prescolite’s Retroficient Series, and Columbia’s upcoming GORK and SLK.


Chris Bailey is the Director of Business Development and Product Innovation for Hubbell Lighting and is responsible for Hubbell Lighting’s Lighting Solutions Center. He is NCQLP Lighting Certified (LC), a LEED-Accredited Professional for Building Design & Construction as granted by the U.S. Green Building Council, DDI certified professional facilitator and a member of the Illuminating Engineering Society (MIES). This article first appears at a Hubbell Lighting blog: http://www.hubbelllighting.com/company/illuminations/money-matters-retrofit-or-relight.

Related Articles


Changing Scene

  • July 10, 2025 - Mac’s II Agencies Announce Addition to Project & Specification Sales Team

    Mac’s II Agencies Announces Addition to Project & Specification Sales Team

    Mac’s II Agencies is pleased to announce that Drazen Jerkovic will be joining their Project & Specification Sales team in the Lighting Division later this fall. With over 25 years of experience in the lighting and electrical industry, Drazen is a highly respected consultant known for his technical knowledge and deep understanding of project delivery. His recent role… Read More…

  • Noramco-Announces-Samantha-Boernsen-as-New-Regional-Sales-Manager-Winnipeg

    Noramco Announces Samantha Boernsen as New Regional Sales Manager, Winnipeg

    Please join Noramco in welcoming Samantha Boernsen as Regional Sales Manager, Winnipeg! Samantha brings a wealth of experience in the electrical industry, with a strong focus on lighting, marketing strategy, and customer engagement. She has built her career on connecting technical expertise with real-world application, making her a trusted partner to clients and colleagues alike.… Read More…


Design

  • Infrastructure Lighting Fixtures: Why Scale Matters

    Infrastructure Lighting Fixtures: Why Scale Matters

    In infrastructure projects, the size and scale of outdoor lighting fixtures are critical—not just for aesthetics, but for functionality, safety, and long-term performance. Whether lighting a streetscape, transit hub, or civic plaza, appropriately scaled fixtures help create environments that are both visually coherent and effectively illuminated. Public lighting plays a role in shaping how spaces… Read More…

  • What You Need to Consider When Choosing Data Center Lighting

    What You Need to Consider When Choosing Data Center Lighting

    When operating a data center, the lighting syst​em is often not the most concerned part. Actually, lighting system performance directly influences whole electricity consumption and operating costs, especially in a 24-hour non-stop data center. This article will delve into the key factors to be considered when choosing data center lighting. For enterprises that are planning to… Read More…


New Products

  • SATCO|NUVO: LED T12 Lamps

    SATCO|NUVO: LED T12 Lamps

    SATCO|NUVO’s LED T12 ballast compatible lamps are direct replacements for T12 linear fluorescent. Offered in a frosted white finish, these lamps are also PET coated and NSF rated. Conveniently sold in two-packs, these lamps make replacing traditional tubes an easy choice. Suggested applications include shop light fixtures, laundry room, utility closets, and garages. Read More…

  • BOLD: Prism Recessed Outdoor Fixture – RL-PRISM-60-BK

    BOLD: Prism Recessed Outdoor Fixture – RL-PRISM-60-BK

    The Prism is part of BOLD’s high-end, durable, and modern 60mm (2 3/8″) recessed fixtures. With its 93 CRI, hexagonal design, partially covered light source, and 360-degree warm glow, you can create unique ambient lighting effects and modern designs, minus the glare. You can safely walk or drive over these raised recessed lights: their low-profile… Read More…