Lighting Systems — An Introduction to ANSI C137.1

February 6, 2017

Roy Harvey

The recently formed ANSI C137 Lighting Systems Committee created a working group to develop a standard for a zero-to-10 volt analog interface between dimmable LED drivers, fluorescent ballasts and dimming controls. At present, there is no widely accepted industry standard for analog dimming of LED sources. The new standard, C137.1, will enhance interoperability of drivers and dimming controls and improve the uniformity of output of multiple drivers operating on the same control circuit.

Photo credit: Osram Sylvania

The standard is based on the 0-10 V fluorescent dimming interface specified in ANSI C82.11 Annex A, which is similar to the interface specified in IEC 60929 Annex E. C137.1 adds several new features and specifies the interface in more detail.

The main new feature is a standby or “electronic off” mode. This optional mode disables the driver’s output power while its control circuitry remains awake. This feature can eliminate a relay used to disconnect the driver’s output and an extra pair of wires to control the relay. Standby mode is entered when the control signal drops below about 0.5 V. C137.1 also adds specifications for dynamic response, the time to start up or change from one level to another.

However, the standard covers more than drivers and ballasts; it also has requirements for dimming controls and system wiring. Like C82.11, C137.1 specifies that the driver or ballast supply current that the control unit sinks and uses to generate the control voltage. C137.1 requires that the control unit manufacturer declare how much current the control unit can sink. This gives a lighting system designer information needed to help ensure that the control unit can handle the current sourced by the driver(s) connected to it. C137.1 also specifies that multiple controls, such as a wall dimmer and a daylight sensor, can connect to the same control wires without damaging each other.

Finally, C137.1 requires that the voltage drop caused by control wiring resistance be no more than 0.3 V. This helps ensure adequate noise margin and uniform operation (light levels) of many drivers sharing control wires. Requirements on tolerances for the endpoints of the dimming range further contribute to uniform operation.

The working group has been developing the standard since February 2015. A draft is being prepared for public review according to the ANSI process. The standard is expected to be published in early 2017, but some of the above information may change, so it is best to check the published edition.

If you have questions regarding these new regulatory requirements or need immediate testing to ensure that your products are in compliance, please contact UL to discuss testing, advisory or training needs at PerformanceLighting@ul.com.


Roy Harvey is SSL Electronics & Infrastructure Standards Manager at Osram Sylvania. He is also Vice-chair of ASC C137 and Head of C137.1 Ad Hoc Group.

 

Related Articles


Changing Scene


Design

  • Stanpro: Guide 101 to Programmable Lighting

    Stanpro: Guide 101 to Programmable Lighting

    Programmable lighting consists of programmable tri-level fixtures with an integrated motion sensor. This type of solution is specifically designed to prevent dissipation of energy in spaces and applications where continuous lighting is the rule. Moreover, programmable lighting is recommended by Hydro-Québec as a tip to adopt good consumption habits. This form of lighting allows the… Read More…

  • CSC LED: Spotted On-Site – Brantford School Lighting Upgrade

    CSC LED: Spotted On-Site – Brantford School Lighting Upgrade

    Upgrading lighting in educational spaces isn’t just about energy savings — it’s about creating environments where students and staff can see clearly, feel comfortable, and stay focused throughout the day. Recently in Brantford, ON, a local school refreshed both its cafeteria and hallways by replacing dim, green-tinted legacy fixtures with CSC LED flat panels. The… Read More…


New Products

  • Eureka: Mill Acoustic Suspended Ceiling Luminaires

    Eureka: Mill Acoustic Suspended Ceiling Luminaires

    Absorb noise in common and public areas with Mill Acoustic Luminaires, for an original soft aesthetic and atmosphere enhancing functionality. With multiple sizes, colors and mounting options, optional uplight as well as an unlit version, Mill will help with volume control while adding a stunning design element to the decor. Read More…

  • SATCO|NUVO: LED Washdown Round High Bays – IP69K | Field Selectable

    SATCO|NUVO: LED Washdown Round High Bays – IP69K | Field Selectable

    SATCO|NUVO’s IP69K Rated LED UFO High Bays are engineered for demanding industrial and hygienic environments where fixtures must withstand high-pressure, high-temperature wash-down procedures. NSF approved and built for food processing, agricultural, and other sanitation-sensitive applications, these fixtures combine rugged durability with field-selectable performance. Wattage selectability (200W/150W/100W) and CCT selectability (4000K/5000K) allow light levels and color… Read More…