Beluce: Scudo-HN Three Phase Inverter

November 18, 2026
Scudo-HN Three Phase Inverter Provides Direct AC Power & Full Illumination to All Lighting Sources
Scudo-HN is a highly efficient inverter that provides power to fixtures to illuminate the path of egress during an emergency. Beluce’s Scudo-HN is a stand-by, three-phase, solid-state two milliseconds (ms) offline fast transfer power supply unit. This inverter features 98% transfer technology efficiency, is user-programable with password protection and operates with low audible noise.
Designed with a compact footprint, the Scudo-HN allows building owners to comply with emergency lighting codes without sacrificing valuable floor-space. Beluce’s Scudo-HN, an emergency lighting inverter, provides up to 50kW of backup power for numerous facilities such as airports, arenas, hospitals, hotels, institutions, office buildings, parking structures, subways and many more.
Features
- 98% Efficient Typical
- PWM/IGBT Technology and Micro-Controller
- Internal Maintenance Bypass
- User Programmable with Password Protection
- Automatic Event, Test and Alarm Log
- RS232 Communications Port
- Input Circuit Breaker
- Low Audible Noise
- Space-Saving Design
- 65kAIC Withstanding Rating
- 2 milliseconds(ms) Transfer Time
Optional Features
- Enhanced Communications
- Expanded Building Management Protocols
- BACnet or Modbus Communications Interface
- IoT Connect Cloud Software (Available 2024)
- External Maintenance Bypass
- Summary Alarm Dry Form C Contacts
- Internal Output Distribution Circuit Breakers
- Normally Off Output
- Output Trip Alarms
- Remote Panels (Meter, Status or Summary Alarm)
Specifications
- Input Voltage: 120/208, 277/480 or 347/600 VAC 3-Phase
- 4-Wire Plus Ground
- Output Voltage: 120/208, 277/480 or 347/600 VAC 3-Phase
- 4-Wire Plus Ground
- Output Load Power Factor 0.5 Lag to 0.5 Lead
- Compatible with all lighting including LED Drivers
- Forced Air Cooling Only During Emergency Operation; No
- Filters Required
- Output Distortion Less than 3% THD for Linear Loads
- Compatible with Generators
- 30, 60, 90 and 120-Minute Runtime available
- Inverter Operating Temperature 0°C to 40°C
- Battery Operating Temperature 20°C to 30°C
- cUL listed to CSA C22.2 No. 141-15
View Scudo-HN Spec Sheet HERE
Audible Alarm
The SCUDO-HN audible alarm will activate with any of the following conditions and automatically store the 50 most recent events:
- High Battery Charger Voltage
- Low Battery Charger Voltage
- High AC Input Voltage
- Low AC Input Voltage
- Near Low Battery Voltage
- Low Battery Voltage
- Load Reduction Fault
- High Ambient Temperature
- Inverter Fault
- Output Fault
- Output Overload
Applications
- Airports Terminals
- Apartment / Condominium Complexes
- Arenas / Stadiums
- Assisted Living Centers & Nursing Homes
- Casinos / Resorts
- Correctional Facilities
- Financial Institutions
- Government Buildings / Public Address Systems
- Hospitals / Clinics
- Hotels / Motels
- Industrial & Commercial Spaces
- Institutional
- Office Buildings
- Parking Structures / Garages
- Race Tracks
- Religious Facilities
- Restaurants
- Retail Department Stores & Malls
- Subways / Mass Transit Stations
- Theaters
Batteries
Batteries do not come pre-installed. They can be shipped together with the unit(s) or shipped separately at a later date (3 or 6 months) with additional charges.
Monitoring & Control
The SCUDO-HN provides operation monitoring and control, audible alarms, LED indicators, and diagnostics. The front-mounted control panel includes a 2-line 20-character LCD display and a keypad to control and monitor the internal operation of the system.
This allows the operator to easily “watch” system functions as they occur and check on virtually any aspect of the system’s operation. Monitoring and control are microcontroller-based for accuracy and reliability. To ensure only authorized personnel can operate the unit, the system is multi-level password protected for all control functions and parameter changes.
For more information on Beluce lighting solutions HERE