Recently the American Medical Association (AMA) produced a document cautioning the public about In-Ga-N based LEDs used as sources of illumination. The Lighting Research Center (LRC) at Rensselaer Polytechnic Institute* has received a large number of requests for an opinion. Professors Mark Rea and Mariana Figueiro of the LRC have prepared a response.

Key points include:

• Predictions of health consequences from light exposure depend upon an accurate characterization of the physical stimulus as well as the biological response to that stimulus. Without fully defining both the stimulus and the response, nothing meaningful can be stated about the health effects of any light source.

• Notwithstanding certain sub-populations that deserve special attention, blue light hazard from In-Ga-N LEDs is probably not a concern to the majority of the population in most lighting applications due to human’s natural photophobic response.

• Both disability glare and discomfort glare are mostly determined by the amount and distribution of light entering the eye, not its spectral content.

• In-Ga-N LED sources dominated by short wavelengths have greater potential for suppressing the hormone melatonin at night than sodium-based sources commonly used outdoors. However, the amount and the duration of exposure need to be specified before it can be stated that In-Ga-N LED sources affect melatonin suppression at night.

• Until more is known about the effects of long-wavelength light exposure (amount, spectrum, duration) on circadian disruption, it is inappropriate to single out short-wavelength radiation from In-Ga-N LED sources as a causative factor in modern maladies.

• Correlated color temperature (CCT) is not appropriate for characterizing the potential impacts of a light source on human health because the CCT metric is independent of nearly all of the important factors associated with light exposure, namely, its amount, duration, and timing.

The LRC’s response attempts to draw attention to the problem of misapplying short-hand metrics to the topic of light and health, and also provides the reader with a wealth of references that should inform rational discourse.

Read about the AMA’s Guidance on Harmful Effects of High Intensity Street Lighting: http://lighting.electricalindustry.ca/led-technology/1502-ama-issues-guidance-on-harmful-effects-of-high-intensity-street-lighting.

Image courtesy of tiverylucky at FreeDigitalPhotos.net.

 

* The Lighting Research Center (LRC) at Rensselaer Polytechnic Institute is the world’s leading center for lighting research and education. Established in 1988 by the New York State Energy Research and Development Authority (NYSERDA), the LRC has been pioneering research in solid-state lighting, light and health, transportation lighting and safety, and energy efficiency for nearly 30 years. LRC lighting scientists with multidisciplinary expertise in research, technology, design, and human factors, collaborate with a global network of leading manufacturers and government agencies, developing innovative lighting solutions for projects that range from the Boeing 787 Dreamliner to U.S. Navy submarines to hospital neonatal intensive-care units. With 35 full-time faculty and staff, 15 graduate students, and a 30,000 sq. ft. laboratory space, the LRC is the largest university-based lighting research and education organization in the world.

 

Related Articles


Changing Scene

  • Aug 6, 2025 - Hèmèra Announces Acquistion by Industry Professionals Francois Renaud, Matthew Curatolo & Nicholas Cohen

    Hèmèra Announces a New Era of Innovation & Leadership

    Hèmèra has announced that it has been acquired by industry professionals François Renaud, Matthew Curatolo, and Nicolas Cohen. This acquisition marks the beginning of an exciting new era for Hèmèra, as the new leadership team is poised to build on the company’s legacy of delivering innovative, high-performance lighting solutions to discerning customers. The new leadership… Read More…

  • July 28, 2025 - Eureka Wins Multiple SIT Furniture Design Awards

    Eureka Wins Multiple SIT Furniture Design Awards

    Eureka is pleased to announce that it has received 2025 SIT Furniture Design Awards for its Junction, Lattice, and Velia luminaires. SIT Furniture Design Award was created to celebrate and share the remarkable work of furniture designers and those who use furniture in their projects. The creativity, innovative vision, and accessibility of the furniture design… Read More…


Design

  • OPTI-SELECT Technology by LEDVANCE: The One Fixture That Does It All

    OPTI-SELECT Technology by LEDVANCE: The One Fixture That Does It All

    OPTI-SELECT is LEDVANCE’s proprietary line of field-adjustable LED luminaires and lamps. Its core idea and unique selling point is that one single fixture can do all the job. Traditional lighting fixtures require ordering a specific SKU for each combination of these specs. On the contrary, OPTI-SELECT combines multiple lighting options in one fixture. It lets you… Read More…

  • Turning the Page on Fluorescent Lighting: Lutron’s C-Flex Solution

    Turning the Page on Fluorescent Lighting: Lutron’s C-Flex Solution

    Starting in 2026, Canada will begin phasing out lamps that contain mercury — including the fluorescent tubes still widely used in commercial, institutional, and public buildings. This regulatory shift only adds to a reality already in place: fluorescent ballasts have not been manufactured for over two years. In anticipation of these changes, Lutron developed C-Flex — a… Read More…


New Products

  • SATCO|NUVO: J-Style Track Beam Adjustable LED Track Heads

    SATCO|NUVO: J-Style Track Beam Adjustable LED Track Heads

    SATCO|NUVO’s beam adjustable, CCT selectable LED J-Style track head fixtures are now compatible with both Single Circuit and 2 Circuit J-Style track systems, expanding their versatility for a wide range of applications. J-Style track, a popular choice in residential and commercial settings, features a streamlined connector design that supports flexible layout configurations. These advanced fixtures… Read More…

  • Cristal: CCLPD-DMX – 0-10V DMX Relay Panels

    Cristal: CCLPD-DMX – 0-10V DMX Relay Panels

    The CCLPD-DMX panels of Cristal Contrôle have been designed respecting the same standards as the distribution panels of electrical rooms in modern buildings. Thanks to this standardization, the installation of relay panels with dimming is quick and easy. The series of CCLPD-DMX relay panels is equipped with the DMX communication protocol and is designed to host HID relay… Read More…