Lighting Systems — An Introduction to ANSI C137.1

February 6, 2017

Roy Harvey

The recently formed ANSI C137 Lighting Systems Committee created a working group to develop a standard for a zero-to-10 volt analog interface between dimmable LED drivers, fluorescent ballasts and dimming controls. At present, there is no widely accepted industry standard for analog dimming of LED sources. The new standard, C137.1, will enhance interoperability of drivers and dimming controls and improve the uniformity of output of multiple drivers operating on the same control circuit.

Photo credit: Osram Sylvania

The standard is based on the 0-10 V fluorescent dimming interface specified in ANSI C82.11 Annex A, which is similar to the interface specified in IEC 60929 Annex E. C137.1 adds several new features and specifies the interface in more detail.

The main new feature is a standby or “electronic off” mode. This optional mode disables the driver’s output power while its control circuitry remains awake. This feature can eliminate a relay used to disconnect the driver’s output and an extra pair of wires to control the relay. Standby mode is entered when the control signal drops below about 0.5 V. C137.1 also adds specifications for dynamic response, the time to start up or change from one level to another.

However, the standard covers more than drivers and ballasts; it also has requirements for dimming controls and system wiring. Like C82.11, C137.1 specifies that the driver or ballast supply current that the control unit sinks and uses to generate the control voltage. C137.1 requires that the control unit manufacturer declare how much current the control unit can sink. This gives a lighting system designer information needed to help ensure that the control unit can handle the current sourced by the driver(s) connected to it. C137.1 also specifies that multiple controls, such as a wall dimmer and a daylight sensor, can connect to the same control wires without damaging each other.

Finally, C137.1 requires that the voltage drop caused by control wiring resistance be no more than 0.3 V. This helps ensure adequate noise margin and uniform operation (light levels) of many drivers sharing control wires. Requirements on tolerances for the endpoints of the dimming range further contribute to uniform operation.

The working group has been developing the standard since February 2015. A draft is being prepared for public review according to the ANSI process. The standard is expected to be published in early 2017, but some of the above information may change, so it is best to check the published edition.

If you have questions regarding these new regulatory requirements or need immediate testing to ensure that your products are in compliance, please contact UL to discuss testing, advisory or training needs at PerformanceLighting@ul.com.


Roy Harvey is SSL Electronics & Infrastructure Standards Manager at Osram Sylvania. He is also Vice-chair of ASC C137 and Head of C137.1 Ad Hoc Group.

 

Related Articles


Changing Scene


Design

  • How Do the Most Trusted Lighting Brands Stay at the Top

    How Do the Most Trusted Lighting Brands Stay at the Top

    In a competitive and constantly evolving lighting market, staying top-of-mind isn’t just about creating beautiful products, it’s about creating consistent value. Lighting professionals today are inundated with choices. From smart solutions and sustainable tech to design-forward fixtures, the options are vast. But amidst this sea of options, some brands always seem to rise to the… Read More…

  • A New Language of Light: Fluxwerx Unveils Speak Recessed Luminaire Family, Reimagining Architectural Integration & Performance

    A New Language of Light: Fluxwerx Unveils Speak Recessed Luminaire Family, Reimagining Architectural Integration & Performance

    Fluxwerx announces the launch of Speak—the latest addition to their expanding collection of LED luminaires for commercial, institutional, retail, hospitality and residential environments. Breaking from the paradigm of conventional downlights, Speak is a new meticulously designed luminaire family that elevates the dialogue between light, material, and spatial intent. Engineered as an extension of architectural form rather… Read More…


New Products

  • Cooper Lighting: Sure-Lites FirstLink – Connected Emergency Lighting

    Cooper Lighting: Sure-Lites FirstLink – Connected Emergency Lighting

    FirstLink is a complete and fully code compliant connected emergency egress lighting system comprised of FirstLink enabled exit signs, unit equipment, emergency LED drivers and the FirstLink application. The app provides easy and instant access to the status of your system. Simply open the app to view and download the condition of all FirstLink devices.… Read More…

  • Eureka Introduces New Tulip Luminaire

    Eureka Introduces New Tulip Luminaire

    Eureka has announced the release of its new Tulip luminaires. The family features a range of fixtures that include chandeliers, pendants and surface mount units. The heart of the Tulip family is a bouquet-inspired arrangement that offers a contemporary take on a classic chandelier. The luminaire is constructed of aluminum tubes and acrylic diffusers. They… Read More…