Parking Garage Lighting Retrofit Reduces Energy Costs, Improves Safety and Aesthetics

January 22, 2019

Located in the heart of the Cote-des-Neiges neighbourhood of Montreal is a large residential development known as Le Sanctuaire. The condominium buildings surround a courtyard with two low-rise commercial structures. One is “ L’Atrium du Sanctuaire” a 38,000 sq.ft. space that is managed by FCR Management Services LP and is home to medical and professional offices, a Jean Coutu pharmacy, and a branch of the Banque Nationale du Canada. The other building contains the chic Midtown Le Sporting Club du Sanctuaire. The two share an underground parking garage, managed by FCR Management Services LP.

Because of the nature of the tenants in both buildings, pedestrian and car traffic volume is extremely high at all times of the day and night. FCR Management Services LP was seeking a lighting solution to improve visibility and safety for both drivers and pedestrians passing through the garage. They turned to the experts at Concept Illumination to evaluate the site and recommend a course of action.

FCR Management Services LP had worked with the Concept Illumination team on other commercial lighting retrofits. “They are reliable, on budget and on time – there are no surprises,” explains Ginette Longpré, Senior Property Manager with FCR Management Services LP.

Upgrading the lighting was necessary for many reasons. While the existing fluorescent lights were doing an adequate job of lighting up the laneways, they did not project sufficient light over the parking spaces, reducing visibility for people accessing their vehicles. The fixtures themselves were deteriorating and maintenance costs were high; the T12 tubes are an aging technology and replacement parts were expensive and very difficult to find.

The retrofit involved installing 105 architectural fixtures, selected to reflect the upscale nature of the building’s surroundings. Each 70W luminaire is 5000K to complement the natural light coming from various skylights. For the most part the fixtures were replaced one for one, but several were eliminated altogether because of the superior lighting coverage with the new lights. The team at Concept Illumination also dramatically improved visibility in building entrances from the garage, as well as a service corridor, with the installation of linear strips. 

The garage ceiling posed a design challenge because of substantial ductwork and piping. Some of the old fixtures were nestled in the midst of these obstructions, so while the light was there it was not distributed to where it should have been.

Concept Illumination’s solution was to lower these particular fixtures by approximately two feet, while keeping them within the required height clearance. “We attached the base of the fixture to the ceiling with a ball joint that has some give, so in the event that they are nudged by pedestrians or larger vehicles they will be protected,” says Daniel Herz, Director of Sales for Concept Illumination.

Managing traffic was the single biggest challenge while completing the retrofit. The goal was to keep the garage open, allowing for regular operations and minimal disruption to pedestrians and cars accessing the space. Herz therefore coordinated the lighting installation so that only one lane would be shut down at a time. Another planning consideration was the fact that the old fixtures were set in concrete, so removal and installation were particularly labour intensive.

The retrofit was successfully completed in one week and the transformation is extraordinary. The overall effect is bright and clean, resulting in a well-lit parking lot. Lighting is uniformly distributed across the laneways, parking spaces and walkways. The architectural fixtures are aesthetically pleasing, offering a comfortable illumination with no hot spots under individual lights.

What cannot be seen by visitors is the anticipated — and significant — energy savings. The 70W LED fixtures replaced 175W 4-tube T12 fluorescent lights, a 60% decrease in energy consumption. FCR Management Services LP can budget for substantial reductions in their operating costs in the months and years to come, and the company is pleased with the results.

“The garage is so much brighter and the lighting is uniform. Garage users feel much more secure now,” said Mrs. Longpré. “The tenant’s comments have been positive.”

Related Articles


Changing Scene

  • The DLC’s New Working Group to Collaborate and Advise on Horticultural Lighting Controls

    May 14, 2024 Lighting and controls manufacturers, engineering and design consultants, non-profits, researchers, and indoor cultivators are among stakeholders recently appointed help the DLC accelerate the horticultural lighting industry’s adoption of networked lighting solutions that advance both crop production and energy efficiency. “The controlled environment agriculture industry has grown steadily since the DLC created its… Read More…

  • CDm2 Lightworks Expands Team in BC’s Interior and Vancouver Island

    May 14, 2024 CDm2 is excited to announce the expansion of their team into the vibrant construction markets of British Columbia’s Interior and Vancouver Island. This expansion is designed to align growth with the dynamic changes in these local economies. “As more companies and industries move to smaller communities, it’s vital that our services grow… Read More…


Design


New Products

  • Introducing MaxLite’s LS3 Series: Controls-Ready LED Strip Lighting

    May 10, 2024 The new generation of LS Series Linear Strips (LS3 Series) features field-selectable wattages, CCTs and field-installable controls. Offered in three sizes (2′, 4′ and 8′), with each providing nine combinations of colour temperatures and wattages, as well as optional c-Max controls, one product can replace 27 different SKUs for stocking distributors! With… Read More…

  • Discover the Power of SATCO|NUVO’s Hi-Pro A21 High Lumen Lamps

    May 10, 2024 SATCO|NUVO’s LED Hi-Pro A21 Lamps offer ColorQuick convenience ideal for commercial projects. Choose from 2700K/4000K/5000K colour temperatures at installation to achieve the desired atmosphere for the environment. Designed to work in 120V to 277V fixtures, these lamps are compatible with ballast bypass fixtures and are dimmable when used in 120V applications. With… Read More…