Lighting Design & Specification

Sept 27, 2020

Lighting WindBy Francis Julien, Junior Mechanical Engineer

The design of outdoor architectural fixtures requires the consideration of multiple environmental factors. These include such validations as Impact Protection (IK), Ingress Protection (IP), and tested operating temperatures. Because outdoor architectural fixtures will be continuously exposed to environmental stresses, such as wind, rain, snow, and ice, the most critical design consideration is safety. Outdoor architectural fixtures are typically installed at heights, the impact of wind on such installations is of primary concern. The impact of wind is typically measured in specification sheets by Effective Projected Area (EPA), but this physical property is only the start of a thorough mechanical analysis to assure safe installations. In this article, we will review EPA, how it is calculated, and how to use it to ensure safe design. We will also discuss the importance of considering worst cases, as well as additional parameters to promote a safe standard design.

What is “Effective Projected Area” and how is it calculated?

The Effective Projected Area is a physical coefficient used to evaluate the wind-induced loads expected on a lighting fixture. It is calculated by multiplying the drag coefficient and the Projected Surface Area of a fixture.

The Projected Surface Area represents the visible area of a three-dimensional shape on a flat plane. To imagine this, picture trying to capture the total area of a common three-dimensional shape such as a cone. If a picture of a cone is taken from the front, its Projected Area (visible shape) will be a triangle (A). If the picture is taken from the top, its projected area will be a circle (B). However, these two perspectives together, and viewed at a variety of angles, form a shape similar to (C).

Lighting Cones

 

 

 

 

 

 

 

 

 

 

The Drag Coefficient is a dimensionless factor obtained through fluid mechanics analysis that is impacted by many factors such as shape and fluid density (water vs. air), etc. Drag Coefficient reflects how much an object suffers from a drag force when in contact with a fluid (the higher the drag coefficient, the higher the loads from wind). While most common shapes are well documented for air Drag Coefficient, complex assemblies like cars, airplanes, and even lighting fixtures can use advanced simulations to obtain the drag force of the whole object.

Drag

How to use the EPA

Once the EPA is properly calculated or relayed via specification sheets, how is it used to assure safe installation? Many standards have been developed from design experience, testing, and environmental data. Good examples are publications such as the [IT]Standard Specification for Structural Supports for Highway Signs, Luminaires, and Traffic Signals[IT] by the American Association of State Highway and Transportation Officials (AASHTO) or the [IT]Canadian Highway Bridge Design Code (CSA-S6-06)[IT] by the Canadian Standards Association (CSA). Although the formulas and coefficients differ from one standard to another, they all consider similar factors. The following section will use the AASTHO standards as an example.

AASTHO refers to wind maps based on many years of compiled meteorological data throughout the United States. For example, wind speeds for Florida are up to 150 miles per hour compared to 90 miles per hour for Kansas. Since this is statistical gust wind speeds for each region, a mounted fixture's design life is considered within the wind pressure equation (probability of occurrence of highest wind speed). Height is also recognised by adding a multiplying factor to account for the fixture's exposure in high installations (approximately 1.5 times the wind pressure for a fixture installed at 230 feet compared to a fixture mounted at 100 feet).

Wind Pressure

To calculate the wind loads on a fixture, wind pressure is calculated for the installation and multiplied by the EPA. AASTHO also specifies regions in the United States were ice storms must be considered. The weight of possible ice accumulation is added to the fixture's weight and the calculated wind loads. Structural analysis can now begin by evaluating if the geometry, material, and fasteners can withstand the applied loads. Other standards should be used according to location, such as the CSA which gives wind pressure and ice accumulation for luminaire installations in Canada.

How to design for worst-case scenarios

In the previous section, we discussed how to use local environmental information from AASTHO or CSA to validate a design’s structural integrity. When designing standard products, the location of each installation may not be known, therefore, worst-case scenarios must be calculated to ensure safety in a variety of environments and scenarios. To identify worst-case scenarios, the wind maps/ice maps are assessed to find the highest environmental loads, however, to fully prepare for a worst-case scenario, the actual physical installation must also be considered. As mentioned in the EPA section above, a cone has a different shape with different drag coefficients based on perspective, a luminaire is no different. The worst-case scenario orientations for a fixture is when the fixture has its highest EPA profile directly exposed to the wind. Its profile is combined with its weight and potential ice loads which induces the highest stress of structural components. Different configurations of a product (length, accessories, etc.) must also be considered to identify worst-case scenarios. 

Worst Case

More than one orientation is often evaluated as multiple stresses can occur on various sections of a fixture. An absolute worst-case is rarely realistic or obtainable without over-designing the product for standard applications. For example, the wind pressure factor shown in the image above will increase with height. Designing a standard fixture to withstand wind loads at the top of a 100-storey building would require a design that is more than two times stronger than needed for more common applications. The worst-case scenarios must be conservative, yet reasonable. For example, it would not be realistic to evaluate fixtures meant for pole lighting at heights of 650 feet.  

After defining the worst-case scenarios and the limitations of fixtures, a factor of safety must also be considered. This safety factor means that the design must be X times stronger than the actual expected worst-case scenario loads. This will take into consideration the possible risks of an underperforming material or exceptional higher loads than expected. A combination of mechanical structural analysis, computer Finite Element Analysis (FEA) simulations, and mechanical/destructive tests are then used to validate that the design maintains the proper safety factor over the specified loads. Standards like AASHTO or CSA often specify minimum required safety factors based on the type of fixture and material used. 

Safe installation: is EPA enough?

As previously mentioned, the EPA is provided in most specification sheets for outdoor luminaire fixtures. While a product should only be released once it has been evaluated to be structurally safe, every installation cannot be controlled. The EPA is specified to help third parties evaluate that they provide a safe installation. A manufacturer's pole guides often refer to maximum weight & EPA for different heights to avoid pole failure. Hardware or wall used to install fixtures on building walls can also be influenced by the EPA and weight. While commonly used and very helpful, the EPA is not always enough to guarantee a safe installation. Some extreme conditions (extreme heights, highly exposed fixtures, vibrations, etc.) can require additional testing or certification or may require a consultation with the supplier to determine a product's limitations. An excellent example of vibration exposed fixtures is bridge installations. Only vibration-rated fixtures should be specified for bridges because wind and traffic-induced vibration significantly increases stress on structural components and fixtures alike.

The ANSI C136.31 standard, Roadway and Area Lighting Equipment - Luminaire Vibration, defines specific vibration testing to certify a luminaire for “Bridge and Overpass Applications.” Even if wind loads are “acceptable” on a bridge using EPA calculations, a non-vibration rated fixture will cause significant safety risks. This shows the importance of properly selecting fixtures as per certifications and cautions us to not only rely upon EPAs. 

The EPAs are calculated following AASHTO standards or using fluid simulation when the luminaire shapes are more complex. While EPAs are published to guide customers during their installations, the fixtures also go through intensive in-house and third-party mechanical and structural testing. It is important to remember that EPA is a coefficient reflecting wind drag on a fixture, during a specific mounting scenario, and not a safety or design limit. EPA is used to determine the amount of stress on a fixture and/or the structure supporting the fixture and is highly dependent on local wind loads. Unique installations with extreme heights, extreme wind speeds, or high vibrational stress should be evaluated following additional standards or structural validation to ensure safe installation.

The future of safety

Lumenpulse is regularly reviewing and researching the most up-to-date standards and discussions regarding the safe mounting and use of outdoor illumination. Lumenpulse designs their products to match the latest standards and ensures the most resilient and secure materials are used in our builds. As climates and testing methods change, so do our designs and security measures. For more information regarding the safest way to mount outdoor luminaires, please contact your Lumenpulse representative or a qualitied engineer of your choice. For more information on mounting Lumenpulse outdoor luminaires on poles, please refer to the Pole Guides located here.

Francis Julien is a Junior Mechanical Engineer with Lumenpulse.

Published with the written permission of Lumenpulse. It was first published online by Lumenpulse; www.lumenpulse.com/knowledge/lighting-outdoor-areas-using-epa.

Changing Scene

  • Prev
Viscor is excited to partner with BIOS to offer circadian light solutions.     ...
The Illuminating Engineering Society’s New York City section have announced 14 winners of the 2020 ...
With a shared commitment to the safety and performance of electrical lighting, UL, the American ...
Leviton announced the appointment and expansion of territory and their lighting and control brands ...
Salex has announced the expansion of its lighting agency to Southwestern Ontario.   ...
The in-person 2020 IES Street and Area Lighting Conference (SALC), originally scheduled ...
The IES Illumination Awards program recognizes individuals for professionalism, ingenuity, and ...
The present pandemic crisis has raised the profile of ultraviolet (UV) technologies designed to ...
The IALD has recently released the Call for Entries for the 38th Annual IALD International Lighting ...
LightFair will be hosted at the Javits Center in New York from May 16-20, 2021. Emerging and ...

Design

  • Prev
When the Government of Canada contemplated developing a co-working concept, they chose Orleans, a ...
Building a control system for a modern lighting installation can seem like an impossibly complex ...
The design of outdoor architectural fixtures requires the consideration of multiple environmental ...
As part of the Lazaridis School of Business and Economics at Wilfrid Laurier University, the ...
When eSentire moved to its new corporate headquarters in Factory Square (Waterloo, Ontario), it ...
Acting as a hub for performing arts in Winnipeg, Canada, the Centennial Concert Hall has long ...
The town of Vanderhoof, British Columbia has built the Vanderhoof Aquatic Centre. A stunning new ...
Whether sitting in a second-floor meeting space, or entering the lobby, it’s impossible not to ...
The 60L from Litecontrol is being used for wall grazing applications throughout ...
Traxon Technologies, an Osram business, is brightening the skyline in San Francisco as ...

LED Technology

  • Prev
While DMX is an industry standard and a workhorse protocol for dynamic lighting controls that ...
The U.S. Department of Energy has released the results of a study examining ...
The rising demand for a strong surveillance system worldwide is likely to boost IR LED market ...
Scientists at the Circadian Light Research Center have identified the narrow band of blue light ...
The Northwest Energy Efficiency Alliance (NEEA) recently published a study seeking to compare ...

New Products

  • Prev
The Appleton Contender low-profile LED luminaire by Emerson is a safe, economical solution for ...
Birchwood Lighting, a Leviton company, announced the launch of the BW165, an all-new small ...
Magic Light announces the newest addition to their In Ground / Wall / Ceiling Disc light ...
The YDD-L is an energy-efficient dusk to dawn yard light. It was designed for barns and ...
Eaton's Wiring Devices AL series dimmers offer a versatile option for any dimming application - ...
Magic Lite's new CCT adjustable T-LED Fixtures. T-LED Edge Light CCT is a modern, ...
Beghelli has expanded their line of hazardous LED lighting line to include each class and division ...
The Klick System by A-LINE, a Liteline brand, is the perfect combination of track and LED fixtures. ...
Liteline Corporation's 4¼" aluminum remodel housing is now available in black in addition to ...
Aculux 2" LED Precision Luminaires With the diminutive 2"Aculux LED precision luminaire, you can ...

Latest News

LightingBy Jason Broadhurst

When the Government of Canada contemplated developing a co-working concept, they chose Orleans, a suburb of Ottawa, for its pilot project. The intent was to open a convenient and comfortable co-working office space closer-to-home than their current downtown location.

Federal employees would use it to avoid rush hour, stay productive during snowstorms, or seek an alternate experience working in the office or working from home.

Read More


 

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2020 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil